Installation

What Size Roof Jack Do You Need for a Swamp Cooler?

Duct opening sizes for Champion, MasterCool, Hessaire and Breezair coolers from their spec sheets, which roof jack each one takes, and why the box CFM picks the wrong jack.

Short answer

Match the roof jack to the cooler's duct opening, not its CFM. A cooler with a 17-3/4 in square opening (Champion 4001, MasterCool 51 series) takes an 18 in jack; one with a 19-3/4 or 20 in opening (Champion 5000, MasterCool 71 series, Hessaire DX6800) takes a 20 in jack. Champion's 3000 has a 13-5/8 in opening that fits neither.

Key takeaways

  • The jack's job is to meet the cooler's discharge opening, so the number to read is the opening on the spec sheet: 13-5/8, 17-3/4 or 19-3/4 in square on Champion's residential line.
  • Sigler's Multi-Pitch jacks come in 18 in and 20 in sizes, with 17-3/4 in and 19-3/4 in discharge openings, and fit flat roofs and pitches up to 6/12.
  • Hessaire names its jacks differently: the DX4800 has a 16-1/2 in opening and still takes Hessaire's 18 x 18 in jack.
  • Buying by box CFM goes wrong at both ends: a 4001 DD sold as 4,900 CFM points to the 20 in jack, and a 3000 points to the 18 in jack. Neither is right.
  • At the openings makers chose, air leaves residential coolers at about 1,400 to 1,650 fpm at 0.3 in of static pressure, so a jack or drop smaller than the opening pushes velocity past the range the site's duct guide targets.
On this page
  1. Roof jack size by cooler model
  2. What the two standard jack sizes are
  3. Why box CFM picks the wrong jack
  4. Why the jack should not be smaller than the opening
  5. Breezair and commercial coolers
  6. Fitting the jack on the roof
  7. Where this stops applying
  8. Frequently asked questions

Match the roof jack to the cooler's duct opening, not to its CFM. A downdraft cooler with a 17-3/4 in square opening, such as a Champion 4001 or a MasterCool 51 series, takes an 18 in jack. One with a 19-3/4 in or 20 in opening, such as a Champion 5000, a MasterCool 71 series or a Hessaire DX6800, takes a 20 in jack. Champion's smallest downdraft, the 3000, has a 13-5/8 in opening that fits neither standard size.

The openings below come from the manufacturers' submittal sheets and manuals, the jack sizes from the jack makers. The roof jack is the sheet metal piece that carries air from the cooler's discharge through the roof deck to the drop below; where it sits in the whole job is in the swamp cooler installation guide.

Roof jack size by cooler model

Each sheet prints the duct opening as two dimensions, and every residential opening on them is square. The jack column pairs that opening with the jack whose discharge opening matches it.

Duct opening and matching roof jack, residential downdraft coolers (manufacturer spec sheets)
CoolerDuct openingOpening areaRoof jack
Champion 3000 DD13-5/8 x 13-5/8 in186 sq inNeither standard size; see below
Champion 4001 DD17-3/4 x 17-3/4 in315 sq in18 in
Champion 5000 DD19-3/4 x 19-3/4 in390 sq in20 in
MasterCool AD C51 and C511217-3/4 x 17-3/4 in315 sq in18 in
MasterCool AD C71 and C711219-3/4 x 19-3/4 in390 sq in20 in
Hessaire DX480016-1/2 x 16-1/2 in272 sq in18 x 18 in (Hessaire 12735)
Hessaire DX680020 x 20 in400 sq in20 x 20 in (Hessaire 12736)
Breezair EXH170 and EXH210Connecting duct 21-5/8 x 21-5/8 in or 19 x 19 in468 or 361 sq inBreezair's own transition

The side discharge versions of the Champion models share the same opening sizes as the downdraft ones on Champion's sheet, but they connect through a wall or a 90 degree transition rather than a roof jack; downdraft vs side draft coolers covers that layout. The 12 at the end of a MasterCool model means 12 in media, which changes the cabinet depth but not the opening.

What the two standard jack sizes are

Russell Sigler sells its Multi-Pitch adjustable roof jack in two sizes and lists the same two discharge openings on both product pages: 17-3/4 in for 3,000 to 4,500 CFM models and 19-3/4 in for 5,500 to 7,000 CFM models. The 18 in jack (part 78317) measures 22 x 22 in across and weighs 8 lb; the 20 in jack (part 78318) measures 24 x 24 in and weighs 10 lb. Both are 28 gauge galvanized steel, flanged, "adjustable for flat roofs and for roofs pitched up to 6/12," and include a slide-in winterizer damper. The 20 in jack adds rails for an optional barometric damper.

Those two discharge openings are exactly the 17-3/4 and 19-3/4 in openings Champion prints for its 4001 and 5000 and MasterCool prints for its 51 and 71 series. That is the whole sizing rule for most rooftop coolers in the Southwest: read the opening, and the jack follows.

Hessaire is the exception that shows why the name on a jack is not a measurement. Its manual says the DX4800 is "designed for use with a 18"X18" adjustable pitch roof jack" and the DX6800 with a 20 x 20 in jack, and tells the installer to "cut square opening according to roof jack size." The DX4800's own discharge is 16-1/2 in square, smaller than the jack it is named for. Use the jack the cooler's maker names when there is one.

Why box CFM picks the wrong jack

Search this question and the common answer is a CFM chart: 18 in for coolers up to about 4,500 CFM, 20 in above that. It circulates because jack makers label their sizes that way. It goes wrong because the CFM on the box and the airflow on the spec sheet are different numbers, and the opening follows the cabinet, not either one.

  • Champion 4001 DD. Retail listings sell it as a "4900 CFM Down-Draft Roof Evaporative Cooler." By CFM band that is a 20 in jack. Champion's sheet gives it a 17-3/4 in opening and a best airflow of 3,654 CFM with the 1/2 hp motor and no duct, as the motor size chart explains. It takes the 18 in jack.
  • Champion 3000 DD. The model number reads like 3,000 CFM, which lands in the 18 in band. The sheet gives a 13-5/8 in opening and 2,175 CFM at zero static pressure. An 18 in jack's 17-3/4 in collar is 4-1/8 in wider than that opening in each direction.
  • Hessaire DX4800 and DX6800. Named 4,800 and 6,800 CFM, Hessaire's own table rates them 3,770 and 5,030 CFM at zero static pressure. Hessaire avoids the problem by naming the jack in the manual.

So treat a CFM band as a hint about which coolers a jack was built for and the opening as the answer. The difference between box and delivered airflow is covered in CFM explained.

Why the jack should not be smaller than the opening

Essick's installation instructions put it in two rules: "Do not 'reduce' the discharge opening of the cooler," and "Do not undersize the duct work and make it much smaller than the discharge opening." The arithmetic shows why. Divide each cooler's delivered airflow by its opening area and you get the air speed through the jack:

Velocity (fpm) = CFM / (opening width (in) x opening depth (in) / 144)
Air speed through the cooler's own duct opening (spec sheet CFM, largest listed motor)
CoolerOpeningCFM at 0 inCFM at 0.3 inVelocity at 0.3 in
Champion 3000 DD, 1/3 hp13-5/8 in2,1751,8101,400 fpm
Champion 4001 DD, 1/2 hp17-3/4 in3,6543,0641,400 fpm
Champion 5000 DD, 3/4 hp19-3/4 in4,9834,2801,580 fpm
MasterCool C51, 3/4 hp17-3/4 in3,7883,2601,490 fpm
MasterCool C71, 1 hp19-3/4 in5,0244,4501,640 fpm
Hessaire DX4800, 1/2 hp16-1/2 in3,7703,0801,630 fpm
Hessaire DX6800, 3/4 hp20 in5,0304,3601,570 fpm

Every residential opening on these sheets puts air through at about 1,400 to 1,650 fpm at 0.3 in of static pressure, close to the 1,500 to 1,800 fpm the ductwork guide uses as a target for the main drop. The makers sized the openings to that range. A jack or drop narrower than the opening pushes velocity above it.

Worked example: a Champion 5000 DD on an 18 in jack

The jack's opening is 17-3/4 x 17-3/4 in, 315 sq in or 2.19 sq ft. At the 4,280 CFM Champion lists at 0.3 in, the air would have to pass at 4,280 / 2.19 = 1,960 fpm, about 24 percent faster than through the cooler's own 19-3/4 in opening. The faster air raises static pressure, and on Champion's sheet, from 0.1 in upward, each added 0.1 in costs the 3/4 hp 5000 DD 240 to 260 CFM. Use the 20 in jack.

The reverse mismatch is a different problem. A cooler with a smaller opening than the jack, like the 3000 DD on an 18 in jack, leaves a gap around the collar that the cabinet does not cover. That is a leak path for rain and attic air, not a speed problem, and it needs a jack or transition made for the smaller opening.

Breezair and commercial coolers

Seeley lists two connecting duct sizes for the Breezair EXH: 21-5/8 x 21-5/8 in or 19 x 19 in. Neither is one of the two standard jack openings, so a Breezair connects through a transition sized to one of those ducts; the Breezair guide covers the system components.

Commercial cabinets have openings no residential jack fits. Champion's sheet gives 21-3/4 in square for the 75/85 SD and 95 SD, 26-7/8 in for the 10/12 SD and 31-3/4 in for the 14/21 SD. MasterCool's AS/AD 100 has a 21-3/4 in opening and the AS/AD 150 a 26-7/8 in one. They mount on curbs or stands sized from their own documents: Essick's CD30 manual, for example, calls for a 70 x 46 in roof opening. Layout for these units is in commercial and warehouse evaporative cooling.

Fitting the jack on the roof

Roof opening
Cut to the jack, not the cooler. Hessaire's manual says to cut the square opening to the roof jack size, 18 x 18 or 20 x 20 in. Whether cutting or enlarging it needs a permit depends on the city; see do you need a permit for a swamp cooler.
Pitch
Sigler's adjustable jacks cover flat roofs up to a 6/12 pitch. The cooler itself must sit level, so the jack takes up the slope between roof and cabinet.
Connection
Goettl's installation instructions say the duct "should have a standing flange over which the cooler discharge opening will fit," so the cabinet sits over the jack collar rather than inside it. Seal the joint to keep rain and hot attic air out.
Weight
The jack carries air, not the cooler. The stand or curb takes the 175 to 360 lb a residential cooler weighs running; see how much a swamp cooler weighs.
Winter
The built-in slide-in damper on a Sigler jack closes the drop in winter. A cover or ceiling seal adds to it, as swamp cooler covers explains.

Where this stops applying

  • Other models. The table covers the models on these sheets. For any other cooler, measure the discharge opening or read it from the submittal sheet before buying a jack.
  • Replacing a cooler on an old jack. If the new cooler's opening is larger than the old jack's collar, the jack and the roof opening both have to grow. A 4001 to a 5000 is that change: 17-3/4 to 19-3/4 in.
  • Velocity figures. They use each sheet's airflow at 0.3 in with the largest motor listed. A smaller motor or more duct resistance moves less air and lowers them.
  • Roofs over 6/12 and unusual decks. Outside the adjustable jack's range, the transition and support have to be built for the roof, and that is a job for the installer and the building department.

Frequently asked questions

What size roof jack for a 4,500 CFM swamp cooler?

Check the duct opening on the cooler's spec sheet rather than the CFM. A 17-3/4 in square opening, like the Champion 4001's and MasterCool 51 series', takes an 18 in jack, and Sigler lists that opening for 3,000 to 4,500 CFM models. A 19-3/4 in opening takes a 20 in jack whatever the box says.

What size roof jack for a Champion 4001 DD?

An 18 in jack. Champion's spec sheet gives the 4001 DD a 17-3/4 x 17-3/4 in duct opening, which is the opening Sigler's 18 in Multi-Pitch jack is made for, even though retail listings sell the cooler as 4,900 CFM.

What size roof jack for a Champion 5000 DD or MasterCool 71?

A 20 in jack. Both have a 19-3/4 x 19-3/4 in duct opening on their spec sheets, the size Sigler lists for 5,500 to 7,000 CFM coolers.

Can I put a bigger cooler on my old roof jack?

Only if the new cooler's duct opening matches the jack. Moving from a 17-3/4 in opening to a 19-3/4 in one means a new 20 in jack and a larger roof opening, and a larger or different unit is also what ends a like-for-like permit exemption in cities that have one.

Does a roof jack work on a steep roof?

Sigler's Multi-Pitch jacks are listed for flat roofs and pitches up to 6/12. A steeper roof is outside that range, so the stand or curb has to be built for it.

Sources and further reading

  1. Champion 3000, 4001 and 5000 DD/SD Specifications and Submittal Data (general specifications), Champion Cooler (Essick Air), hosted by Appliance Factory Parts
  2. MasterCool AD/AS C51, C5112, C71 and C7112 Specifications and Submittal Data, Champion Cooler, hosted by Appliance Factory Parts
  3. Champion 75/85 SD, 95 SD, 10/12 SD and 14/21 SD Specifications and Submittal Data, Champion Cooler (Essick Air), hosted by Baker Distributing
  4. MasterCool AS/AD 100 and AS/AD 150 Specifications and Submittal Data, Champion Cooler, hosted by Appliance Factory Parts
  5. Hessaire DX4800 and DX6800 Owner's Manual (installation and specifications), Hessaire, hosted by The Home Depot
  6. Technical Specifications: Breezair Icon EXH170, EXH210, Seeley International
  7. Multi-Pitch Adjustable Roof Jack 18 in, 28ga (78317), Russell Sigler, Inc.
  8. Multi-Pitch Adjustable Roof Jack 20 in, 28ga (78318), Russell Sigler, Inc.
  9. Essick CS16 Industrial/Commercial Owner's Guide (duct work), Essick Air Products, hosted by Appliance Factory Parts
  10. Essick CD30 and CD36 Installation Guide and Owner's Manual (roof opening), Essick Air Products, hosted by Appliance Factory Parts
  11. Installation and Operating Instructions for Goettl Evaporative Coolers, Goettl Air Conditioning, hosted by InspectApedia
  12. Champion 4900 CFM Down-Draft Roof Evaporative Cooler for 1800 Sq. Ft. (retail listing), Do it Best