Installation

How Much Does a Swamp Cooler Weigh on the Roof?

Shipping and operating weights for Champion, MasterCool and Breezair coolers from their spec sheets, the load per square foot, and why the roof figure is higher.

Short answer

A residential rooftop swamp cooler weighs about 175 to 360 lb running, with its motor, wet pads and full water pan. That operating weight, not the 110 to 250 lb shipping weight retailers list, is what the roof carries. Commercial units run from about 450 lb to almost 1,100 lb.

Key takeaways

  • Champion's 3000, 4001 and 5000 series weigh 175 to 357 lb in operation against 109 to 220 lb shipped, and Champion's shipping figure leaves out the motor.
  • Side discharge Champions weigh 18 to 48 lb more in operation than the matching downdraft model, even though they ship lighter.
  • MasterCool's 51 and 71 series run 233 to 306 lb; 12 in media adds about 30 lb of operating weight over 8 in media on the same cabinet.
  • Spread over its own footprint, a Champion downdraft puts about 29 to 32 lb per square foot on the roof, above the 10 and 20 psf dead loads the IRC rafter span tables are built on.
  • A Breezair EXH weighs about 200 lb in operation because its polypropylene cabinet and 2.9 gallon tank are light, so it loads the roof at under half the rate of a steel downdraft.
On this page
  1. Residential cooler weights by model
  2. Why two different weights circulate
  3. Side draft runs heavier than downdraft
  4. What that weight means for the roof, per square foot
  5. Commercial cooler weights
  6. Using the numbers on a real job
  7. Where these numbers stop applying
  8. Frequently asked questions

A residential rooftop swamp cooler weighs about 175 to 360 lb when it is running, counting the motor, saturated pads and a full water pan. That operating weight is what the roof carries. The figure most product pages show is the shipping weight, roughly 110 to 250 lb, which is what two people lift up the ladder. Commercial units run from about 450 lb to almost 1,100 lb in operation.

The numbers below come from the manufacturers' own submittal sheets, the documents contractors hand to building departments. This page covers weight and what it means for the roof; the rest of the job is in the swamp cooler installation guide.

Residential cooler weights by model

Champion's spec sheet for its 3000, 4001 and 5000 series gives two weights with two footnotes: "Shipping weight is without motor" and "Operating weight shown is total weight of unit, motor and water." MasterCool's 51 and 71 series sheet, printed on Champion Cooler letterhead, lists operating and shipping weights for each model, and Seeley International gives shipping and operating mass for the Breezair EXH.

Shipping and operating weight, residential coolers (manufacturer spec sheets)
ModelDischargeMediaShipping weightOperating weightAdded in service
Champion 3000DDDownAspen118 lb175 lb+57 lb
Champion 4001DDDownAspen161 lb233 lb+72 lb
Champion 5000DDDownAspen220 lb309 lb+89 lb
Champion 3000SDSideAspen109 lb193 lb+84 lb
Champion 4001SDSideAspen150 lb269 lb+119 lb
Champion 5000SDSideAspen202 lb357 lb+155 lb
MasterCool AD/AS C51Down or side8 in rigid184 lb233 lb+49 lb
MasterCool AD/AS C5112Down or side12 in rigid204 lb263 lb+59 lb
MasterCool AD/AS C71Down or side8 in rigid220 lb269 lb+49 lb
MasterCool AD/AS/AU C7112Down, side or up12 in rigid246 lb306 lb+60 lb
Breezair EXH170DuctedChillcel183 lb199 lb+16 lb
Breezair EXH210DuctedChillcel185 lb201 lb+16 lb

The MasterCool model numbers above are the spec sheet's (AD1C7112 at 115 V, AD2C7112 at 230 V, and so on); the voltage version does not change the weight. The 12 at the end of a MasterCool model means 12 in media, as the pad sizes by model chart explains.

Why two different weights circulate

Search for this question and you will find answers from "about 100 lb" to "several hundred pounds." Both are real numbers. The low ones are shipping weights, copied from retail listings, and the high ones are what installers feel on a roof stand. For anything structural, the operating weight is the one that counts.

Three things separate them:

  • The motor. Champion ships its residential coolers without one, so its shipping weight leaves the blower motor out entirely. MasterCool's sheet lists "Thermostat, pumps & motor included" among the features of the 51 and 71 series.
  • Water in the pan. The reservoir stays filled to the level the float valve is set to hold, high enough to keep the pump intake submerged.
  • Water in the pads. Wet media holds water on every face. Thicker media holds more: MasterCool's 12 in media version of the same cabinet weighs about 30 lb more in operation than the 8 in version (263 against 233 lb for the 51 series, 306 against 269 lb for the 71), but only 20 to 26 lb more to ship.

Breezair sits at the other end. The EXH cabinet and reservoir are injection moulded polypropylene and Seeley lists a tank capacity of just 2.9 gallons, so its operating mass is only 16 lb above its shipping mass. The EXH210, rated 5,400 cfm at 0.3 in of static pressure, weighs less in operation (201 lb) than Champion's steel 4001SD (269 lb). If roof load is a deciding factor between brands, that is a real difference; the Breezair guide covers the rest of the trade-off.

Side draft runs heavier than downdraft

Champion's table holds a detail most comparison pages miss. Each side discharge model ships lighter than its downdraft twin (109 against 118 lb for the 3000) but weighs more once it is running: 18 lb more for the 3000, 36 lb for the 4001 and 48 lb for the 5000. At 357 lb, the 5000SD is the heaviest residential unit on the sheet. Champion's sheet gives the totals without breaking them down, so the reason is not stated there.

That matters most when a side draft goes on a wall bracket or a roof stand rather than a slab on the ground. Use the operating weight from your own model's sheet when you choose the bracket. Downdraft vs side draft coolers covers the other differences between the two layouts.

What that weight means for the roof, per square foot

Total pounds tell you what to lift. Pounds per square foot tell you how hard the cooler presses on the roof under it. Divide the operating weight by the cabinet's footprint:

Load (psf) = Operating weight (lb) / (Width (in) x Depth (in) / 144)

Worked example: Champion 4001DD

The cabinet is 34 1/8 in wide and deep. 34.125 x 34.125 = 1,164 sq in, divided by 144 is 8.09 sq ft. 233 lb / 8.09 sq ft = 28.8 lb per square foot.

Operating load over the cabinet footprint
ModelFootprint (in)Operating weightLoad over footprint
Champion 3000DD28 1/8 x 28 1/8175 lb32 psf
Champion 4001DD34 1/8 x 34 1/8233 lb29 psf
Champion 5000DD39 x 39309 lb29 psf
Champion 5000SD39 x 39357 lb34 psf
MasterCool C711242 x 52306 lb20 psf
MasterCool C5142 x 45233 lb18 psf
Breezair EXH21045.7 x 45.7201 lb14 psf

For scale: the IRC sizes rafters from Tables R802.4.1(1) through (8), and the tables give spans for a dead load of 10 psf or 20 psf, which covers the weight of the roof itself spread evenly. A steel Champion downdraft is about 29 to 34 psf over its footprint, more than either column. That does not mean the roof will fail, because the stand spreads the load across several framing members. It means the cooler is a concentrated load the span tables do not cover, which is why R802.4.1 sends "other loading conditions" to the AWC span tables, and why the installation guide insists the stand bear on rafters or truss top chords rather than on sheathing.

Commercial cooler weights

Commercial units are a different weight class, and their operating weight rises with the motor fitted. Both sheets list one operating weight per motor size:

Operating weight, commercial coolers (manufacturer spec sheets)
ModelMotor optionsOperating weightFootprint (in)
Champion 75/85 SD3/4 to 1 hp450 to 456 lb41 1/4 x 41 1/4
Champion 95 SD1 1/2 to 2 hp466 to 470 lb41 1/4 x 41 1/4
Champion 10/12 SD1 to 2 hp719 to 733 lb50 x 50
Champion 14/21 SD1 1/2 to 5 hp1,040 to 1,087 lb62 x 62
MasterCool AS/AD 1001 1/2 to 5 hp757 to 804 lb82 x 45
MasterCool AS/AD 1502 to 7 1/2 hp907 to 984 lb85 1/4 x 48 1/4

The motor is a large share of the spread. The AS/AD sheet lists motor weights of 41 lb at 1 1/2 hp, 50 lb at 2 hp, 83 lb at 3 hp, 87 lb at 5 hp and 121 lb at 7 1/2 hp. Over their footprints, the Champion commercial units come to roughly 39 to 42 psf. Sizing and layout for these units are covered in commercial and warehouse evaporative cooling.

Using the numbers on a real job

Replacing like for like
Compare the old unit's operating weight with the new one's. A 4001DD to a 5000DD adds 76 lb in operation; a Champion 4001DD to a MasterCool C7112 adds 73 lb on a larger footprint. A larger or different unit is also what ends a like-for-like permit exemption in the cities that have one; see do you need a permit for a swamp cooler.
Lifting it up
Plan the lift around the shipping weight, with the pan drained and pads dry. Champion's residential cabinets are 109 to 220 lb without the motor, so hanging the motor after the cabinet is on the stand keeps the lift at the lower figure. What a crew charges for a rooftop swap is in the installation cost guide.
Platform
Section M1413 of the IRC, as Washington adopts it, requires evaporative coolers to be installed on level platforms. That applies to a ground slab or wall bracket as much as to a roof stand.
Window units
The same distinction applies on a smaller scale: the bracket has to be rated above the unit's operating weight, not its shipping weight, as window cooler installation explains.

Where these numbers stop applying

  • Other brands and models. The tables cover the models on these specific spec sheets. For anything else, get the operating weight from your own unit's submittal sheet or manual; do not assume a similar CFM means a similar weight, as the Breezair figures show.
  • Media changes. Swapping aspen pads for rigid media, or 8 in media for 12 in, changes the wet weight. The MasterCool figures put 12 in media at about 30 lb more than 8 in on the same cabinet. Aspen vs rigid media covers the trade-offs.
  • Roof stands and roof jacks. The weights above are the cooler alone. The stand, the roof jack and any duct drop hanging from them are additional.
  • Structural judgment. Per-square-foot figures show why the load needs framing under it; they are not a structural calculation. Old, damaged or altered framing, or a heavier unit going where a lighter one sat, is a question for the building department or a licensed engineer.

Frequently asked questions

How much does a swamp cooler weigh with water?

Champion lists operating weights, which include the unit, motor and water, of 175 lb for a 3000DD, 233 lb for a 4001DD and 309 lb for a 5000DD. MasterCool's 51 and 71 series range from 233 to 306 lb, and Breezair's EXH170 and EXH210 are 199 and 201 lb.

Can my roof hold a swamp cooler?

Most homes in the Southwest have carried one for decades, but the answer depends on the framing under the stand, not on the roof as a whole. A cooler is a concentrated load of 30 lb or more per square foot of footprint, above the uniform dead loads the IRC rafter tables assume, so the stand has to land on rafters or truss chords. A new installation or a heavier replacement is a question for the building department or an engineer.

Is a side draft cooler heavier than a downdraft?

In Champion's line, yes once it is running. The 3000SD, 4001SD and 5000SD weigh 193, 269 and 357 lb in operation against 175, 233 and 309 lb for the downdraft versions, even though the side discharge models are lighter to ship.

How much does a commercial swamp cooler weigh?

Champion's 75/85SD weighs 450 to 456 lb in operation, its 10/12SD 719 to 733 lb and its 14/21SD 1,040 to 1,087 lb, depending on the motor. MasterCool's AS/AD100 runs 757 to 804 lb and the AS/AD150 907 to 984 lb.

How heavy is a swamp cooler to lift onto a roof?

Use the shipping weight, with the pan drained and the pads dry. That is 109 to 220 lb for Champion's residential models without the motor, and 184 to 246 lb for MasterCool's 51 and 71 series. Fitting the motor after the cabinet is up takes that weight off the lift.

Sources and further reading

  1. Champion 3000, 4001 and 5000 DD/SD Specifications and Submittal Data (general specifications), Champion Cooler (Essick Air), hosted by Appliance Factory Parts
  2. Champion 75/85 SD, 95 SD, 10/12 SD and 14/21 SD Specifications and Submittal Data, Champion Cooler (Essick Air), hosted by Baker Distributing
  3. MasterCool AD/AS C51, C5112, C71 and C7112 Specifications and Submittal Data, Champion Cooler, hosted by Appliance Factory Parts
  4. MasterCool AS/AD 100 and AS/AD 150 Specifications and Submittal Data, Champion Cooler, hosted by Appliance Factory Parts
  5. Technical Specifications: Breezair Icon EXH170, EXH210, Seeley International
  6. Rafter Spans (IRC R802.4.1 and Tables R802.4.1(1) to (5)), Greene County, Georgia
  7. WAC 51-51-1413, Evaporative cooling equipment (IRC M1413), Washington State Legislature