HUD's rules for a roof-mounted cooler on a manufactured home, the 20, 30 and 40 psf roof load zones against real cooler weights, and Arizona's permit and license rules.

Short answer

Yes. HUD's installation standards expect roof-mounted evaporative coolers on manufactured homes, but the cooler must be listed, the installer must first make sure the roof will hold it, and it must sit on a rigid base that spreads its weight over several roof trusses. A steel downdraft presses about 29 to 32 lb per square foot on its footprint, above the 20 psf most Southwest homes are built for. A side-draft on a ground pad avoids the roof load entirely.

Key takeaways

  • HUD's Model Installation Standards (24 CFR 3285.503) allow a roof-mounted cooler if it is listed, the roof is confirmed to carry it, and a rigid base spreads it across multiple trusses.
  • The HUD Code designs manufactured home roofs for a uniform live load of 20 psf in the South Zone, 30 psf in the Middle Zone and 40 psf in the North Zone. Arizona, New Mexico, Nevada and Texas are South Zone; Colorado and Utah are Middle Zone.
  • Champion's 3000, 4001 and 5000 downdrafts weigh 175, 233 and 309 lb running, which is about 32, 29 and 29 psf over their own cabinets. That is 45 to 60 percent more than a South Zone roof is designed to carry.
  • A cooler that is not on the roof only has to follow its listing or the maker's instructions, whichever is stricter, so a side-draft on a pad takes the roof question off the table.
  • In Arizona a cooler attached to a manufactured or mobile home is an accessory structure: it needs a permit from the Department of Housing (or a participating local office), and the cooler, roof jack, wiring and water are licensed I-10C work.
On this page
  1. Mobile home or manufactured home: which rules apply
  2. What the HUD Code builds a manufactured home roof to carry
  3. Cooler weight against a 20 psf roof
  4. The two answers you will find, and which is right
  5. Off the roof: side-draft, pad mount and window units
  6. Arizona: a permit and a licensed installer
  7. New Mexico and other states
  8. Rooftop or ground: the choice in one table
  9. What this page does not settle
  10. Frequently asked questions

Yes, you can put a swamp cooler on a mobile home, and on the roof if you want it there. HUD's installation rules for manufactured homes plan for it. They set three conditions. The cooler must be listed. The installer must first make sure the roof will hold it. And it must sit on a rigid base that spreads its weight over several roof trusses. What you cannot do is set a steel downdraft straight on the roof. It presses down harder than most Southwest roofs are built to carry.

This page puts the numbers side by side: the roof load the HUD Code builds to, the weight of real coolers, and the rules in Arizona and New Mexico for who may do the work. The rest of the job is in the swamp cooler installation guide.

Mobile home or manufactured home: which rules apply

Most people say "mobile home" for any factory-built home on a steel chassis. The law splits them by date. Arizona's statute, A.R.S. 41-4001, defines a mobile home as one built before June 15, 1976. A manufactured home is one built to the federal standards that took over after that date, known as the HUD Code (24 CFR Part 3280).

That date matters here. The roof load figures below come from the HUD Code, so they apply to manufactured homes. A home built before June 1976 was not built to them. Its roof has to be judged on its own framing.

Two more terms carry the rest of the page:

Roof live load
The weight a roof is designed to carry on top of its own weight, such as snow or a person walking on it. The HUD Code says these loads "shall be considered to be uniformly distributed," which means spread evenly over the whole roof.
Operating weight
What a cooler weighs while it runs: the cabinet, the motor, wet pads and a full water pan. It is the weight the roof feels, and it is well above the shipping weight on the box.

What the HUD Code builds a manufactured home roof to carry

Section 3280.305(c)(3) sets the minimum roof live load by zone. The zone is applied "downward on the horizontal projection," so it is pounds per square foot of floor plan under the roof.

Manufactured home roof live load by HUD roof load zone (24 CFR 3280.305(c)(3))
ZoneDesign roof live loadWhere (examples)
South20 psfEvery state and county not listed for the other two zones, including Arizona, New Mexico, Nevada, Texas and California
Middle30 psfAll counties of Colorado, Utah, Idaho, Montana and Wyoming, plus listed counties in the northern states
North40 psfAll of Alaska and eight counties in northern Maine

Two things in the section shape the cooler question. First, it says nothing about rooftop equipment. The only concentrated load anywhere in 3280.305 is for floors: a 200 lb load on a one inch disc. Second, every home carries a data plate, a label posted inside the home. It names the home's roof load zone, or the actual design snow load if the home was built for more. Read yours before you trust the table. A home built for a heavier zone than its location needs will say so there.

Cooler weight against a 20 psf roof

Champion's submittal sheet lists the operating weight of its residential downdrafts as the "total weight of unit, motor and water." Divide that by the cabinet's footprint and you get how hard the cooler presses on the patch of roof right under it. The site's cooler weight guide has the full table for other brands.

Footprint load (psf) = Operating weight (lb) / (Width (in) x Depth (in) / 144)

Worked example: a Champion 4001DD on a South Zone home

Take a single-wide in Arizona with a data plate that says South Zone, 20 psf. Suppose the owner wants a Champion 4001DD on the roof. Its cabinet is 34-1/8 in square. That is 34.125 x 34.125 = 1,164 sq in, or 8.09 sq ft. The sheet gives an operating weight of 233 lb.

233 lb / 8.09 sq ft = 28.8 psf. That is 44 percent more than the 20 psf the roof was designed to carry, and it is a steady load, not a passing one.

Now work it the other way. To bring the cooler alone down to 20 psf, its weight would have to spread over 233 / 20 = 11.7 sq ft. That is a base about 41 in square. Even then, that patch of roof would be carrying its full design live load all summer, before the base, the jack or a person servicing the cooler is counted.

The same math for Champion's other two downdrafts:

Champion downdraft footprint load against HUD roof load zones (Champion submittal sheet; 24 CFR 3280.305)
ModelCabinetOperating weightFootprint loadArea for 20 psf
Champion 3000DD28-1/8 x 28-1/8 in175 lb31.9 psf8.8 sq ft (about 36 in square)
Champion 4001DD34-1/8 x 34-1/8 in233 lb28.8 psf11.7 sq ft (about 41 in square)
Champion 5000DD39 x 39 in309 lb29.3 psf15.5 sq ft (about 47 in square)

Every one of them is over 20 psf on its own footprint. The smallest unit has the highest number, because its cabinet is small for its weight. In the Middle Zone, the 4001DD and 5000DD come in just under 30 psf and the 3000DD just over. That zone's figure is set for snow, though, and snow keeps falling on the roof around a cooler.

The two answers you will find, and which is right

Search this question and you get two kinds of answer. Search "best swamp cooler for mobile home" and the top results are RV lists and product roundups: yes, buy this model. General how-to pages lean the other way and steer you to the ground, to avoid roof leaks and ladder work. None of them gives a roof load number or names the rule.

The federal rule settles it. HUD's Model Installation Standards, 24 CFR 3285.503(a)(3), have a paragraph just for evaporative coolers. A roof-mounted cooler must:

  1. Be listed. It must be listed or certified by a nationally recognized testing agency for its use and installed to the terms of that listing.
  2. Have its roof checked first. "Before installing a roof-mounted evaporative cooler on-site, the installer must ensure that the roof will support the weight of the cooler."
  3. Sit on a rigid base. "A rigid base must be provided to distribute the cooler weight over multiple roof trusses."
  4. Keep its grill clear of the smoke alarm. No discharge grill may be closer than 3 ft to a smoke alarm.

So the roof is allowed: the federal standard expects roof coolers, and "keep it on the ground" is a preference, not a rule. But "yes, buy this model" is wrong as advice. It skips the base and the roof check that the standard requires. The numbers above show why the base is the point. A cooler set right on the roof puts all its weight on whatever framing lies under its cabinet. A rigid frame spanning several trusses shares it out.

The same section treats a cooler off the roof very differently. One "that is not roof-mounted" only has to follow its listing or the maker's instructions, "whichever is the more restrictive." No roof check, no base across trusses.

Off the roof: side-draft, pad mount and window units

A side-draft cooler blows out the side of its cabinet. On a mobile home it usually sits on a concrete pad or a steel stand beside the house and blows through a wall opening or a duct. Champion's side-draft models run heavier than its downdrafts: 193, 269 and 357 lb in operation for the 3000SD, 4001SD and 5000SD. On a pad, that weight goes into the ground, not the home. How the duct path changes airflow is covered in downdraft vs side-draft coolers.

A window evaporative cooler is the smaller step. It cools one to three rooms, and its cabinet rests on a bracket fastened to the wall framing or on a stand on the ground. It never hangs from the window sash.

Whichever you choose, the cooler needs a way out for the air it pushes in. HUD's public housing guide to installing swamp coolers says "a window should be cracked open" when one runs, and that coolers and air conditioners "should never be used together to cool the same space at the same time." How big that opening should be is worked out in venting and relief air.

Arizona: a permit and a licensed installer

Arizona is the clearest case, because its law names the cooler. A.R.S. 41-4001 defines an "accessory structure" to include an "evaporative cooler" attached to a manufactured home or mobile home. The Arizona Department of Housing's Office of Manufactured Housing regulates those, along with the homes.

  • Permit. Rule R4-34-801(A) says a properly licensed entity or person "shall obtain a permit" for an attached accessory structure. The Department issues it, or a local office that has an agreement with the Department. The permit expires six months after it is issued, and the permit holder or owner must request the inspections.
  • License. Rule R4-34-204 gives the I-10C general installer license this scope: install evaporative cooler systems on manufactured and mobile homes, "provides roof jack to cooler ducts," installs exterior duct work, "provides electrical service and controls to cooler from nearest supply source," provides water "from nearest fresh water source," and "performs cooler repair work." The I-10G master installer may do the same work. The I-10D license covers attached accessory structures, including their mechanical equipment.
  • Plans. Rule R4-34-705(C) calls for plans sealed by an Arizona registered engineer for attached accessory structures, with two exceptions: skirting with maker instructions, and HVAC systems. The rule does not say in so many words whether a cooler counts as an HVAC system, so ask the Office before you assume you need, or can skip, a sealed plan.

So in Arizona the roof jack, the circuit and the water line are all part of one licensed, permitted job. The roof jack size chart covers which jack fits which cooler, and breaker and wire size covers the circuit.

New Mexico and other states

New Mexico's Manufactured Housing Division rule, 14.12.2 NMAC, does not mention coolers by name. It licenses repairmen by class. An MHD-2 may make "structural repairs and alterations." An MHD-3 adds service and repair of plumbing and electrical systems. Work outside the home itself, including concrete beyond small pads for support posts, is not part of those classes. It falls under the state's Construction Industries Licensing Act. A rooftop cooler touches the roof framing, the wiring and the water, so it reaches into MHD-2 and MHD-3 work. Ask the Division which license and permit it wants for your job.

In Clark County, Nevada, items installed on or attached to a manufactured home are permitted and inspected by the Nevada Manufactured Housing Division, not the county. The cooler permit guide has the city rules for site-built homes.

Rooftop or ground: the choice in one table

Where to put a swamp cooler on a manufactured home, and what each choice requires
SetupWhat the rules requireRoof loadSource
Rooftop downdraftListed unit; installer confirms the roof will support it; rigid base across multiple trusses; grill at least 3 ft from a smoke alarmAbout 29 to 32 psf on its own footprint (Champion), against 20, 30 or 40 psf by zone24 CFR 3285.503(a)(3)(i); 3280.305(c)(3)
Side-draft on a pad or standFollow the listing or the maker's instructions, whichever is stricterNone on the roof24 CFR 3285.503(a)(3)(ii)
Any cooler attached to the home, ArizonaPermit from the Department of Housing or a participating local office; I-10C, I-10G or I-10D licenseeDepends on the setup aboveA.R.S. 41-4001; R4-34-801; R4-34-204

What this page does not settle

The footprint math shows why a rooftop cooler needs a base across several trusses. It is not a check of your roof. It does not tell you whether your trusses, their spacing or their condition will carry a given cooler on a given base. That is the installer's job under 3285.503, and on an old, damaged or altered roof it is a question for an engineer. The base, the stand, the roof jack and the duct drop all add weight the table leaves out. Homes built before June 15, 1976 have no HUD roof load zone at all. Weights here are Champion's; get your own unit's operating weight from its submittal sheet. Last, the Arizona rules assign the permit to "a properly licensed entity or person." Whether a homeowner may pull one for their own home is not stated in the rules quoted here, so ask the Office of Manufactured Housing before you start.

Frequently asked questions

Can a mobile home roof hold a swamp cooler?

It can if the cooler sits on a rigid base that spreads its weight over several roof trusses and the installer confirms the roof will carry it, which is what 24 CFR 3285.503 requires. Set straight on the roof, a Champion 4001DD presses about 29 lb per square foot, against a 20 psf design roof load in the South Zone.

What is the roof load on a manufactured home?

The HUD Code sets a minimum roof live load of 20 psf in the South Zone, 30 psf in the Middle Zone and 40 psf in the North Zone, treated as spread evenly over the roof. The zone, or a higher design load if the home was built for one, is printed on the data plate inside the home.

What kind of swamp cooler is best for a mobile home?

The one whose weight you can carry without guessing. A side-draft on a ground pad puts no load on the roof at all. A rooftop downdraft works on a rigid base across several trusses after someone confirms the roof. A window unit cools one to three rooms and hangs on a wall bracket or stands on the ground.

Do I need a permit to put a swamp cooler on a mobile home in Arizona?

Yes. Arizona law lists an evaporative cooler attached to a manufactured or mobile home as an accessory structure, and Arizona's rule R4-34-801 requires a permit for an attached accessory structure. The Department of Housing issues it, or a local office that has an agreement with the Department.

Does a mobile home built before 1976 have a roof load rating?

Not under the HUD Code. Arizona defines a mobile home as one built before June 15, 1976, and the HUD Code's roof load zones apply to manufactured homes built to it. An older home has no data plate zone to check, so the roof has to be judged on its own framing.

Sources and further reading

  1. 24 CFR 3280.305, Structural design requirements (roof load zones in paragraph (c)(3)), Legal Information Institute, Cornell Law School
  2. 24 CFR 3285.503, Optional appliances (evaporative coolers in paragraph (a)(3)), Electronic Code of Federal Regulations
  3. Champion 3000, 4001 and 5000 DD/SD Specifications and Submittal Data (general specifications), Champion Cooler (Essick Air), hosted by Appliance Factory Parts
  4. A.R.S. 41-4001, Definitions (accessory structure, manufactured home, mobile home), Arizona State Legislature
  5. Ariz. Admin. Code R4-34-204, Installers (license classes I-10C, I-10D, I-10G), Legal Information Institute, Cornell Law School
  6. Ariz. Admin. Code R4-34-801, Permits, Legal Information Institute, Cornell Law School
  7. Ariz. Admin. Code R4-34-705, Accessory Structures, Legal Information Institute, Cornell Law School
  8. Installation Permits, Arizona Department of Housing, Office of Manufactured Housing
  9. 14.12.2 NMAC, Manufactured Housing General Provisions (14.12.2.14, installer and repairmen license classes), New Mexico State Records Center and Archives
  10. Building Simple Permits, Clark County Building and Fire Prevention
  11. PHECC ECM H11: Install Swamp Coolers (archived copy, March 2025), U.S. Department of Housing and Urban Development