Brands and Buying

Champion vs MasterCool Swamp Cooler: Who Makes MasterCool, and Which to Buy

MasterCool is a Champion brand. Champion 3000, 4001 and 5000 aspen coolers vs MasterCool 51, 5112, 71 and 7112 rigid media: CFM, size, weight, rebates and price.

Short answer

Champion and MasterCool are the same company. Both trademarks belong to Essick Air Products and Champion Cooler Corporation, so the real choice is aspen pads (Champion 3000, 4001, 5000) or rigid media (MasterCool 51, 5112, 71, 7112). The 4001 and the MasterCool 51 series share a 17-3/4 in duct opening; the 5000 and the 71 series share 19-3/4 in. Only the 12 in MasterCools qualify for El Paso Electric and PNM rebates.

Key takeaways

  • MasterCool is not a separate maker. Both mastercoolproducts.com and championcooler.com say MasterCool and Champion are registered trademarks of Essick Air Products, Inc. and Champion Cooler Corporation.
  • Match by duct opening: Champion 4001 and MasterCool ADA51/ADA5112 are 17-3/4 in; Champion 5000 and ADA71/ADA7112 are 19-3/4 in. The Champion 3000 (13-5/8 in) has no MasterCool match.
  • On the same motor, the aspen Champion moves more air: 4,280 CFM for a 5000DD at 3/4 hp against 3,888 for an ADA7112 at 3/4 hp, both at 0.3 in static pressure.
  • Only the 12 in MasterCools (5112, 7112) are on El Paso Electric's and PNM's rebate lists. The 8 in MasterCools sit on Xcel's $300 standard tier, the same tier as the aspen Champions.
  • At one dealer on November 3, 2026, a 12 in MasterCool cabinet cost $831 to $874 more than the Champion with the same duct size. A $1,000 El Paso Electric rebate covers that; PNM's $400 covers about half.
On this page
  1. Who makes MasterCool
  2. What the two lines actually are
  3. The models side by side
  4. Airflow on the same motor
  5. Worked example: replacing a 5000DD
  6. Rebates by model
  7. Street price
  8. Which one to buy
  9. What this comparison does not cover
  10. Frequently asked questions

Champion and MasterCool are made by the same company, so "Champion vs MasterCool" is really aspen pads vs rigid media from one maker. The footer of mastercoolproducts.com reads: "Essick Air®, AIRCARE®, MasterCool®, Champion®, UltraCool®, Super Wick®, Masterstat®, Masterlink®, MoistAir® and Trapmax® are registered trademarks of Essick Air Products, Inc. and Champion Cooler Corporation." The championcooler.com footer carries the same sentence. Champion's own site lists "Portable & Rigid Media Coolers by MasterCool®" among its family brands.

So the useful question is which cabinet fits your roof and your rebate. Match the two lines by duct opening. A Champion 4001 and a MasterCool 51 series share a 17-3/4 in opening. A Champion 5000 and a MasterCool 71 series share 19-3/4 in. If your utility is El Paso Electric or PNM, only the 12 in MasterCools (5112 and 7112) earn a rebate.

Who makes MasterCool

Four separate records point the same way:

  • The trademark notice. Both maker sites name Essick Air Products, Inc. and Champion Cooler Corporation as owners of the MasterCool and Champion marks.
  • Champion's brand menu. championcooler.com sorts its family into "Aspen Media Coolers by Essick Air®," "Portable & Rigid Media Coolers by MasterCool®" and "Humidifers by AIRCARE®."
  • The paperwork. MasterCool's C51 to C7112 submittal sheet carries the Champion Cooler name and its Little Rock, Arkansas address, the same as the Champion 3000 to 5000 sheet.
  • The rebate lists. El Paso Electric files every MasterCool under manufacturer "Essick Air," brand "Champion." PNM lists "Champion Master Cool," made by Essick Air. Xcel Energy Colorado lists the maker as Champion.

Why do people think otherwise? Retailers name these coolers three different ways ("MasterCool by Champion," "Champion ADA71 MasterCool," or plain "MasterCool"). Phoenix Manufacturing (PMI) also sells a competing rigid media line, AeroCool Pro, and it appears beside MasterCool on the same utility lists. Some brand guides, including earlier versions of ours, credited MasterCool to Phoenix Manufacturing. The lists file AeroCool, Trophy, Frigiking and Brisa under PMI, and MasterCool under Champion. Our Phoenix Manufacturing guide now covers PMI's own lines.

What the two lines actually are

A few terms decide this comparison, so here they are in plain words.

Champion (in this comparison)
The 3000, 4001 and 5000 coolers. Each is a square steel box with an aspen pad on each side. Aspen pads are mats of shredded aspen wood that hold water while air is pulled through them. DD means down discharge (the air goes down through the roof). SD means side discharge.
MasterCool
The 51, 5112, 71 and 7112 coolers. Each is a long box with one thick block of rigid media at one end. Rigid media is stiff, stacked sheets of corrugated paper. The 51 and 71 use an 8 in deep block; the 5112 and 7112 use 12 in. ADA is down discharge, ASA is side discharge and AUA is up discharge.
Saturation effectiveness
How much of the gap between outdoor temperature and wet bulb temperature the pad closes. At 90%, the pad closes 90% of the gap. Rebate programs set the bar at 85%.
Static pressure
The resistance your duct puts on the fan, in inches of water. A cooler moves less air as it rises. Both makers publish airflow at 0 to 0.6 in. This page compares at 0.3 in, a typical ducted figure; see CFM explained.

Champion also sells rigid media under its own name: the Champion Elite 4000 RLD4 is on Xcel's and PNM's lists at 90%. That model is outside this comparison.

The models side by side

The Champion figures are from Champion's submittal sheet (dated 8-08). The MasterCool figures are from MasterCool's current ADA specification sheet. Both are down discharge models.

Champion aspen vs MasterCool rigid media, matched by duct opening (all dimensions in inches)
ModelMediaDuct openingCabinet H x W x DOperating weightMotor optionsBelt
Champion 3000DD4 aspen pads, 27 x 2213-5/833-7/16 x 28-1/8 x 28-1/8175 lb1/3 hp4L-450
Champion 4001DD4 aspen pads, 28 x 2717-3/434-1/2 x 34-1/8 x 34-1/8233 lb1/3 or 1/2 hp4L-560
MasterCool ADA511 rigid block, 22-1/4 x 41-1/4 x 817-3/428 x 42 x 45227 lb1/3, 1/2 or 3/4 hp52 in (53 in at 3/4 hp)
MasterCool ADA51121 rigid block, 22-1/4 x 41-1/4 x 1217-3/428 x 42 x 49257 lb1/3, 1/2 or 3/4 hp52 in (53 in at 3/4 hp)
Champion 5000DD4 aspen pads, 36 x 3319-3/442-7/16 x 39 x 39309 lb1/2 or 3/4 hp4L-690
MasterCool ADA711 rigid block, 28-7/8 x 41-1/4 x 819-3/434-5/8 x 42 x 48263 lb1/2, 3/4 or 1 hp64 in
MasterCool ADA71121 rigid block, 28-7/8 x 41-1/4 x 1219-3/434-5/8 x 42 x 52300 lb1/2, 3/4 or 1 hp64 in

Champion's operating weight is the unit, motor and water together. MasterCool's sheet does not say what its operating weight includes. Its older Contractor line sheet, with the motor fitted, gives 233, 263, 269 and 306 lb for the same four sizes.

Three things stand out. First, the Champion 3000 has no MasterCool partner. The smallest MasterCool needs a 17-3/4 in opening, so swapping it onto a 3000's 13-5/8 in jack means a new jack; see what size roof jack. Second, the shapes differ. A Champion is a cube. A MasterCool is a wide, low box 45 to 52 in long, so a same-size duct does not mean the same stand or curb. Third, the weights are close. The heaviest MasterCool, the ADA7112, weighs within 9 lb of the 5000DD. More on roof loads in how much a swamp cooler weighs.

Neither cabinet comes with a motor in its basic version. Champion's shipping weight is "without motor," and dealers sell the cabinets as "cabinet only." MasterCool's sheet says motor and pulley are "sold and shipped separately" for ADA models. Its Contractor line (AD1C51 to AD2C7112) has "the same specifications" but comes "fully assembled and ready to install with motor, pump, pulley, purge system, and deluxe thermostat." Motor sizing is covered in what size motor, and belts in belt size by model.

Airflow on the same motor

The aspen Champion moves more air than the MasterCool on the same motor. The thick rigid block resists airflow more than four thin pads.

CFM at 0.3 in static pressure, from each maker's fan table
Duct sizeMotorChampionMasterCool 8 inMasterCool 12 in
17-3/4 in1/3 hp4001DD: 2,240ADA51: 2,060ADA5112: 1,997
17-3/4 in1/2 hp4001DD: 3,064ADA51: 2,650ADA5112: 2,564
17-3/4 in3/4 hpNot offeredADA51: 3,260ADA5112: 3,135
19-3/4 in1/2 hp5000DD: 3,300ADA71: 3,270ADA7112: 3,212
19-3/4 in3/4 hp5000DD: 4,280ADA71: 3,940ADA7112: 3,888
19-3/4 in1 hpNot offeredADA71: 4,450ADA7112: 4,394

To match a Champion's airflow, a MasterCool needs one motor size up. The MasterCool's larger motor option is what makes up the gap. A 1 hp ADA7112 moves 4,394 CFM against the 3/4 hp 5000DD's 4,280.

Ignore the numbers in the product names. MasterCool calls the ADA51 a 5,000 CFM "industry standard rating" cooler with a 3/4 hp motor. Its own fan table gives 3,788 CFM at zero pressure and 3,260 at 0.3 in. Retailers call the 4001DD a 4,900 CFM cooler, while Champion's table tops out at 3,654.

Worked example: replacing a 5000DD

Worked example: 5000DD at 3/4 hp vs ADA7112 at 1 hp, on a 19-3/4 in jack

Take the site's standard design day: 100 F outside, 66 F wet bulb, a 34 F gap. Champion publishes no effectiveness rating for its aspen pads. Suppose they run 70%, the middle of the 60 to 80% range for aspen in our aspen vs rigid media guide. The ADA7112's 12 in media is rated 90% on Xcel's list.

Supply air works out like this. Champion: 100 - 0.70 x 34 = 76.2 F. MasterCool: 100 - 0.90 x 34 = 69.4 F. That is 6.8 F colder air from the MasterCool.

Now the cooling a house at 80 F would get, using 1.08 x CFM x (room temperature - supply temperature). Champion: 1.08 x 4,280 x 3.8 = about 17,600 BTU/h. MasterCool: 1.08 x 4,394 x 10.6 = about 50,300 BTU/h. The figure swings a lot with the room temperature you pick, but the order does not change.

Colder air costs water. With the site's rule, gallons per hour = CFM x temperature drop / 8,186: Champion 4,280 x 23.8 / 8,186 = about 12.4 gal/h. MasterCool 4,394 x 30.6 / 8,186 = about 16.4 gal/h, before bleed-off.

Try your own climate in the cooling temperature calculator. On a humid monsoon day with a small gap, the difference between pads shrinks; on a dry day it grows.

Rebates by model

This is where the two lines split most sharply. The 8 in MasterCools get no more rebate than the aspen Champions.

Rebate list status (Xcel 2020 Colorado list; El Paso Electric Rev. 07/20/2026; PNM 7/21/2026)
ModelXcel Energy ColoradoEl Paso ElectricPNM
Champion 3000, 4001, 5000 DD/SDStandard tier, $300Not listedNot listed
MasterCool ADA/ASA 51, 71 (8 in)Standard tier, $300Not listedNot listed
MasterCool ADA/ASA 5112, ADA/ASA/AUA 7112 (12 in)"Upgradeable," rated 90%: $675 with a remote thermostat and purge pump on the receiptListedListed
MasterCool Contractor line C5112, C7112 (12 in)Premium, rated 90%, thermostat and purge pump included: $675, or $1,200 multi-ductedListedListed

El Paso Electric's list says "Eligible evaporative coolers must have a Saturation Effectiveness ≥ 85%." Its New Mexico page pays $600 per unit, with "Up to $1,000 per qualifying unit" through December 15, 2026, while funds last. PNM's list is for its $400 rebate on 2026 installs. Xcel's $675 premium tier needs "1) a remote thermostat, 2) a periodic purge pump, and 3) a media saturation effective rating of 85% or higher." Xcel names the Champion thermostat kit 110423-2 with the standard pump, or a Dial 7617 thermostat with a built-in purge pump. Without them on the receipt, "it will be considered a standard cooler ($300 rebate)." The $1,200 tier needs at least three supply ducts, with at least one duct and diffuser new.

The brief version: if you buy a MasterCool for the rebate, buy the 12 in. The full program rules are in swamp cooler rebates by utility, and the 8 in vs 12 in trade is in 8 inch vs 12 inch media.

Street price

Prices below are cabinet only, with no motor, from one online dealer (Snook HVAC) on November 3, 2026. One dealer gives a like-for-like set; other stores price these cabinets differently.

Cabinet-only prices, Snook HVAC, November 3, 2026
Duct sizeChampion (aspen)MasterCool 8 inMasterCool 12 in
13-5/8 in3000DD: $913.15NoneNone
17-3/4 in4001DD: $900.00ADA51: $1,122.34ADA5112: $1,773.95
19-3/4 in5000DD: $1,304.40ADA71: $1,472.02ADA7112: $2,135.84

The 12 in MasterCool costs $873.95 more than a 4001DD and $831.44 more than a 5000DD. The rebate decides whether that gap is real:

  • El Paso Electric New Mexico. The Champion gets nothing; the 12 in MasterCool gets up to $1,000 through December 15, 2026. The rebate covers the whole gap.
  • PNM. The Champion gets nothing; the 12 in MasterCool gets $400, about half the gap.
  • Xcel Energy Colorado. The Champion gets $300; the 12 in MasterCool gets $675 if you add the thermostat and purge pump. The net difference is $375, less the cost of those parts.
  • No rebate. You pay the full gap for colder air and longer media life. The 8 in MasterCool is the middle option: $168 to $222 more than the matching Champion, with the same rebate status.

The MasterCool also needs a motor one size larger to match the Champion's airflow, so add that to its side. For installed costs, see what a swamp cooler costs.

Which one to buy

  • You have a 13-5/8 in jack and want a drop-in swap. The Champion 3000 is the only one of these that fits it.
  • You are in El Paso Electric or PNM territory. Buy the 12 in MasterCool that matches your duct size. The rebate pays for most or all of the price gap.
  • You want the cheapest cabinet and do your own pad changes. Buy the Champion. On the same motor it moves more air, and it has the lowest cabinet price in each duct size.
  • You were going to buy an 8 in MasterCool for a rebate. Don't. It sits on Xcel's standard tier with the aspen Champions and is not on the El Paso Electric or PNM lists.
  • Your roof is tight on space. Measure first. The MasterCool is 42 in wide and 45 to 52 in long, against 34-1/8 in square for a 4001 and 39 in square for a 5000.

For service, parts and the rest of the company's lineup, see the Champion and Essick Air guide.

What this comparison does not cover

The prices are one dealer on one day, without motors, and they move. The Champion sheet is from 2008 and MasterCool's Xcel rating comes from Xcel's 2020 list; Xcel says it pays only on its current approved list, so check your model when you apply. The 70% aspen figure is an assumption, because Champion publishes no rating, and real aspen effectiveness falls as the pads age and scale. Rebates are first come, first served. The tables cover down discharge models; side discharge versions share duct sizes but differ in weight. Not covered: Champion's Elite rigid media models, window coolers, portables and commercial sizes. A cooler swap on a roof still needs a roof that can carry it, a stand or curb that fits the new footprint, and any local permit; see do you need a permit.

Frequently asked questions

Who makes MasterCool swamp coolers?

Essick Air Products and Champion Cooler Corporation, the same company that makes Champion and Essick Air coolers. The trademark notice on both mastercoolproducts.com and championcooler.com says so, and MasterCool's submittal sheet is printed on Champion Cooler letterhead.

Does Phoenix Manufacturing make MasterCool?

No. Phoenix Manufacturing (PMI) makes AeroCool, AeroCool Pro, AeroCool Trophy, Frigiking and Brisa coolers. Utility rebate lists file MasterCool under Champion and Essick Air, and AeroCool under Phoenix Manufacturing.

Can a MasterCool replace a Champion on the same roof jack?

The duct size can match: a Champion 4001 and a MasterCool ADA51 or ADA5112 both have a 17-3/4 in opening, and a Champion 5000 and an ADA71 or ADA7112 both have 19-3/4 in. The cabinet shape does not match, so the stand or curb and the duct position need checking.

Do MasterCool coolers come with a motor?

It depends on the model. The ADA, ASA and AUA models are sold with the motor and pulley separate. The Contractor line (model numbers with C, such as AD1C5112) comes assembled with motor, pump, pulley, purge system and thermostat.

Is the Champion 4001 really 4,900 CFM?

Not on Champion's own fan table. Its submittal sheet gives the 4001DD a top of 3,654 CFM at zero static pressure with a 1/2 hp motor, and 3,064 CFM at 0.3 in. Compare coolers by the fan table at the same static pressure, not by the name on the box.

Sources and further reading

  1. MasterCool home page (trademark notice in footer), Essick Air Products / MasterCool
  2. Champion Cooler home page (family brands menu and trademark notice), Champion Cooler
  3. MasterCool Residential Evaporative Coolers (ASA, ADA, AUA models and resources), Essick Air Products / MasterCool
  4. MasterCool ADA51, ADA5112, ADA71, ADA7112 specifications and Single Inlet Contractor Line, Essick Air Products / MasterCool
  5. MasterCool AD/AS C51, C5112, C71 and C7112 Specifications and Submittal Data (6-10), Champion Cooler
  6. Champion 3000, 4001 and 5000 DD/SD Specifications and Submittal Data (8-08), Champion Cooler
  7. Colorado Evaporative Cooling Qualified Equipment List (2020 program year), Xcel Energy
  8. Evaporative Cooling Rebates, Xcel Energy Colorado (Energy Federation Inc.)
  9. Evaporative Cooler Eligibility List, Rev. 07/20/2026, El Paso Electric
  10. Evaporative Cooling: New Mexico residential energy rebate, El Paso Electric
  11. Qualified Advanced Evaporative Coolers ($400 Rebate for 2026 Installs), 7/21/2026, PNM
  12. Champion 3000DD Down Draft Evaporative Cooler Cabinet, Snook HVAC
  13. Champion 4001DD Down Draft Evaporative Cooler Cabinet, Snook HVAC
  14. Champion 5000DD Evaporative Cooler Cabinet, Snook HVAC
  15. Mastercool ADA51 Down-Draft Evaporative Cooler Cabinet, Snook HVAC
  16. Mastercool ADA5112 Down-Draft Evaporative Cooler Cabinet, Snook HVAC
  17. Champion ADA71 MasterCool Down Draft Evaporative Cooler Cabinet, Snook HVAC
  18. Mastercool ADA7112 Evaporative Cooler Cabinet, Snook HVAC