Will a Swamp Cooler Damage Hardwood Floors?
Flooring warranties ask for 35 to 55% humidity. Cooler homes sit near 43 to 56% in June and 12 to 24% in winter. Wood moisture and board movement by city.
Short answer
Not by its humidity in dry weather. Modeled across six Western cities, a vented cooler keeps indoor air at about 43 to 56% RH on June afternoons, close to the 35 to 55% that Bruce and Hurst flooring warranties ask for. Winter heating drops the same homes to 12 to 24%, below the band, and that is when gaps open. The cooler itself is the risk in three cases: monsoon afternoons near 70% in Phoenix and Tucson, too little relief air, and water dripping from a ceiling register.
Key takeaways
- Bruce (AHF Products) and Hurst Hardwoods both ask you to keep indoor humidity between 35% and 55%. Damage from low or high humidity is not covered by Bruce's warranty.
- On June afternoons with the cooler running, modeled indoor RH runs 43 to 56% in Denver, Albuquerque, Las Vegas, Tucson, El Paso and Phoenix. That puts the wood at about 8 to 10% moisture.
- Winter heating without a humidifier puts the same homes at 12 to 24% RH and the wood at about 3 to 5%. A 5 in red oak plank shrinks about 0.08 in between June and January.
- Phoenix and Tucson cooler afternoons in July and August average 68 to 71% RH. That is above the warranty band, and it is the season for swelling and cupping.
- Liquid water is the real damage case. A drip from a ceiling register or pad carryover wets wood far past anything humid air can do, and Bruce excludes water damage.
On this page
- Two terms the answer depends on
- What the flooring warranties ask for
- Indoor humidity in cooler homes, by city
- Worked example: one red oak floor in Albuquerque
- Board movement by species
- When a swamp cooler does damage a floor
- Why two answers circulate
- What to do in a cooler home with wood floors
- What these numbers do not cover
- Frequently asked questions
A swamp cooler will not damage hardwood floors through its humidity in dry weather. On a June afternoon with the cooler running, a vented home in the desert West sits at about 43 to 56% relative humidity. The flooring makers checked here ask for 35 to 55%. Winter is the season that falls outside that band. Heating the same homes with no humidifier drops them to 12 to 24%, and that is when gaps open between boards. The cooler becomes the risk in three cases: monsoon afternoons near 70% in Phoenix and Tucson, too little relief air, and water that drips from a ceiling register.
This page gives the humidity, the wood moisture and the board movement for six cities, and then the cases where a cooler really does hurt a floor.
Two terms the answer depends on
Relative humidity (RH) is how much water vapor the air holds compared with the most it could hold at that temperature. A cooler adds water vapor. Warming the same air lowers its RH.
Equilibrium moisture content (EMC) is the moisture level wood settles at in a given air. The U.S. Forest Products Laboratory defines it as the moisture content "at which the wood is neither gaining nor losing moisture." It is a percent of the wood's dry weight. Wood in 70 F air at 50% RH settles at 9.2%. At 15% RH it settles at 3.5%. Those figures come from Table 4-2 of the lab's Wood Handbook.
When EMC goes up, boards swell. When it goes down, they shrink. Almost all of that movement is across the width of a board, not along its length. That is why seasonal damage shows up as gaps between boards, or as boards that cup. Cupping means the edges of a board rise above its center. Bruce lists cupping among the results of high humidity and excessive moisture.
What the flooring warranties ask for
Bruce, sold by AHF Products, says "For best results, keep the relative humidity in your home between 35% and 55%." Its warranty guide excludes splits, cracks, shrinking, cupping and bowing caused by "improper environmental conditions (i.e., low or high humidity)." It adds that "The use of a humidifier/dehumidifier may be necessary" to stay in range. It also excludes "Natural expansion and contraction resulting in separation between boards." Floors damaged by water, including leaking pipes and spills, are excluded as well.
Hurst Hardwoods, a flooring seller, uses the same band: "Relative humidity between 35% - 55% must be maintained throughout the life of the floor." Hurst says some species shrink and crack more easily below 35%. It names Jatoba (Brazilian cherry), Ipe, Santos mahogany, Wenge, Cumaru, Douglas fir, hard maple and Tigerwood. It also warns that the top layer of engineered flooring can shrink, crack and delaminate below 35%.
One detail is often quoted wrong. Bruce's "at or below 85 F" limit applies to the floor surface over radiant heat. It is not a room temperature rule for every home.
Indoor humidity in cooler homes, by city
To get real numbers, this page takes five years (2021 to 2025) of hourly weather from NASA's POWER data set for six cities. It takes each summer afternoon hour from 11 am to 7 pm at 85 F or hotter. It runs that air through rigid media at 85% efficiency, the figure the indoor humidity guide uses. The supply air then warms to 78 F in the house, or 3 F above supply on the hottest hours. Winter is December to February, with outdoor air heated to 68 F and no moisture added. Wet bulb and RH come from PsychroLib at each site's air pressure. EMC comes from the Wood Handbook's Equation 4-5, which reproduces Table 4-2.
| City | June, cooler on | August, cooler on | Winter, heated to 68 F | June, cooled to 78 F with no moisture added |
|---|---|---|---|---|
| Denver | 43% RH, 8.1% EMC | 46%, 8.5% | 12%, 2.9% | 19% |
| Albuquerque | 47%, 8.7% | 55%, 10.0% | 15%, 3.6% | 21% |
| Las Vegas | 52%, 9.5% | 62%, 11.4% | 19%, 4.4% | 20% |
| El Paso | 53%, 9.7% | 63%, 11.4% | 18%, 4.2% | 26% |
| Tucson | 53%, 9.7% | 70%, 13.1% | 22%, 4.9% | 23% |
| Phoenix | 56%, 10.2% | 71%, 13.3% | 24%, 5.3% | 22% |
Three rulings come out of the table.
- Dry months with a cooler: inside the band or at its top edge. Every June figure is 43 to 56%. Phoenix, at 56%, is one point over. A cooler home in June meets the warranty band better than a home cooled with no moisture added, which sits at 19 to 26%.
- Winter: below the band in every city. Heated air with no humidifier runs 12 to 24%. One hour in ten is drier still, at 7 to 12%. That has nothing to do with the cooler, which is shut down for winter. Bruce's fix is a humidifier during the heating season "to prevent excessive shrinkage in hardwood floors, which causes gaps between the boards." The same swing matters for acoustic guitars and pianos, as the guitar and piano humidity page sets out against Taylor's and Steinway's bands.
- Monsoon months in the low desert: above the band. Phoenix and Tucson afternoons average 70 to 71% in August with the cooler on. Las Vegas and El Paso run 62 to 63%. Those are the weeks when a cooler pushes a floor toward swelling. The monsoon season guide covers when to switch the pump off.
Wood does not follow every afternoon. The Wood Handbook says moisture changes "usually are gradual, and short-term fluctuations tend to influence only the wood surface." The floor tracks the average over days and weeks. Nights and cool mornings with the pump off are drier than the afternoon figures, so the real floor sits below the "cooler on" column.
Worked example: one red oak floor in Albuquerque
Worked example: how much a 5 in plank moves from June to January
Take a flatsawn northern red oak floor with 5 in boards in an Albuquerque living room. Flatsawn boards move by the tangential rate, the larger of the two across-grain rates. Suppose the cooler runs on June afternoons and the house is heated to 68 F in winter with no humidifier.
June, cooler on: 47% RH at 78 F, so the wood heads toward 8.7% EMC. Winter: 15% RH at 68 F, so it heads toward 3.6%. That is a drop of 5.1 points.
The winter figure is under 6%, the low end of the Handbook's dimensional change table. For that case the Handbook gives Equation 13-4, which uses the green-to-dry shrinkage of the species. Northern red oak shrinks 8.6% tangentially (Table 4-3). Worked through: 5 x 5.1 / (3,000 / 8.6 - 30 + 8.7) = 25.5 / 327.5 = 0.078 in.
So each board loses about 0.078 in of width, near 5/64 in. That is about the thickness of a U.S. nickel. Across a 12 ft room, about 29 boards wide, the floor gives up roughly 2.3 in in total. Most of it shows as a thin gap at each board edge. Hard (sugar) maple shrinks 9.9%, so the same swing gives 0.091 in per board and about 2.6 in across the room.
Now move the house to Phoenix and use August instead of June. The wood goes from 13.3% to 5.3%, a swing of 8 points. A red oak board then moves 0.12 in, about 1/8 in. Maple moves 0.14 in.
The gap is not damage by itself. It closes again in summer. The risk is the boards that cannot close or open evenly, the species Hurst names as prone to cracking, and finishes that crack as boards move.
Board movement by species
The Wood Handbook lists a dimensional change coefficient for each species in Table 13-5. It is the share of width a board gains or loses for each 1 point change in moisture, valid from 6% to 14%. Multiply it by the board width and the change in EMC (Equation 13-3).
| Species | Coefficient (tangential) | Per 1 point of EMC | Albuquerque June to winter | Phoenix August to winter |
|---|---|---|---|---|
| Red oak, northern red | 0.00304 | 0.015 in | 0.078 in | 0.121 in |
| Maple, sugar (hard maple) | 0.00353 | 0.018 in | 0.091 in | 0.140 in |
| White oak | 0.00376 | 0.019 in | 0.097 in | 0.149 in |
| Courbaril (Jatoba, Brazilian cherry) | 0.00300 (from Table 4-4 shrinkage) | 0.015 in | 0.077 in | 0.119 in |
The last two columns use Equation 13-4, because the winter EMC falls below 6%. Jatoba is not in Table 13-5. Its coefficient here comes from its 8.5% tangential shrinkage in Table 4-4, run through the Handbook's Equation 13-2. Quartersawn boards move at the radial rate, about half as much (northern red oak 0.00137).
When a swamp cooler does damage a floor
Humid air moves a floor slowly and mostly back and forth. Three cooler problems do lasting harm.
Water dripping from a ceiling register
Liquid water is a different scale of problem. Even 95% RH air brings wood only to about 24% EMC in Table 4-2. Standing water can take it to the fiber saturation point, which the Handbook puts at about 30%. Water from a register usually comes from pad overspray, an overfilled pan or a cooler that is out of level. The swamp cooler leaking guide traces each one. Bruce excludes floors damaged by water, including leaking pipes and spills, so a register drip is not a warranty claim. Put a towel or tray under a dripping register and fix the cooler the same day.
Pad carryover
Carryover is droplets that blow off over-wet pads into the duct. It adds water without cooling. It can land as a fine mist on the floor under the register, or it can soak the duct until it drips. Signs are damp spots near registers or mist you can feel in the supply air. The too humid guide lists the fixes: troughs that do not overflow, seated pads and a level cabinet.
Too little relief air
A cooler pushes damp air into the house, and that air has to leave. With windows shut, the house fills with supply air, which leaves the pads at roughly 70 to 85% RH. Room RH climbs well past 55% and stays there. That is the swelling and cupping risk, and it can happen on a dry day. Open windows on the far side of the house, or add up-ducts, as the venting and relief air guide sizes them. A cooler that is sized for the house with relief to match keeps humidity in check.
Why two answers circulate
One answer says coolers ruin wood floors. The other says they are fine. Both are describing real cases. A dripping register or a sealed-up house on a monsoon day does swell and stain wood. A vented cooler in a dry June keeps the house nearer the warranty band than most other ways to cool. Neither answer mentions winter, which is when every home in these six cities falls below 35%.
The installation moisture matters too. The Wood Handbook (Table 13-2) recommends 6% for interior flooring in the dry Southwest, with single pieces from 4 to 9%. A floor laid at 6% in a cooler home will reach 9 to 10% in June. In Phoenix it could head toward 13% in August. Laid in a home cooled with no moisture added, the same floor stays closer to 6% through June. A cooler home calls for the expansion space the installer leaves at the walls. The Handbook says to leave space at the edges of large floors "to allow for some expansion."
What to do in a cooler home with wood floors
- Put a hygrometer in the room with the floor. Read it after the cooler has run an hour, and again in January.
- Keep summer readings at 55% or below. Open more relief area first. If it still sits above 55% on a humid afternoon, run fan-only or turn the cooler off for those hours.
- Treat any wet register as urgent. Dry the floor, then fix the water level, pads or tilt before running the pump again.
- Add humidity in winter if you want to stay in the warranty band. Bruce recommends a humidifier in the heating season.
- Close the cooler for winter. A cold open duct lets heated air escape and can drip condensation. The winterizing guide covers the damper and cover.
What these numbers do not cover
The city figures are a model of a typical vented house, not a reading from yours. They assume 85% media, a house at 78 F and a cooler running on hot afternoons. Aspen pads, a warmer house or a cooler run all evening will change them. NASA's data is for a grid square around each city, not a street. The winter figures leave out moisture from cooking, showers, people and plants, so a lived-in house reads somewhat higher. The Wood Handbook says its EMC values suit practical use but vary by species and by whether wood is drying or wetting. Movement figures are for solid flatsawn boards; engineered floors, laminate and bamboo behave differently, so check the maker's own limits. This page does not cover moisture from below, such as a damp crawl space or slab, which cups floors with any cooling system. The warranty terms quoted are Bruce's and Hurst's. Read your own floor's warranty before you rely on a number here. Water already on a floor or in a ceiling is a matter for a restoration contractor, not a hygrometer.
For how the cooler adds moisture in the first place, and how wet bulb sets the limit, see wet bulb temperature explained. If humidity has to stay low all year, indirect evaporative cooling adds little or no moisture to the house.
Frequently asked questions
What humidity is safe for hardwood floors?
The two flooring sources checked here both say 35% to 55% relative humidity. Bruce's warranty guide says to keep the home in that range and may require a humidifier or dehumidifier to do it. Hurst Hardwoods says the range "must be maintained throughout the life of the floor".
Is a swamp cooler or AC better for hardwood floors?
In dry months the cooler home is closer to the warranty band. Cooling outdoor air to 78 F without adding moisture, as refrigerated air does in a dry climate, gives about 19 to 26% RH on a June afternoon in the six cities modeled here, below the 35% floor. In Phoenix and Tucson in August, the AC home sits inside the band at 47 to 49%, and the cooler home runs above it at 70 to 71%.
Why do my hardwood floors have gaps in winter?
Heated desert air is very dry. With no humidifier, the six cities modeled here average 12 to 24% indoor RH from December to February, which brings wood to about 3 to 5% moisture. Each flatsawn 5 in red oak board loses about 0.08 in of width from June, and the gaps close again when summer humidity returns.
Can a swamp cooler cause hardwood floors to cup?
It can when indoor humidity stays high for weeks or when water reaches the floor. Bruce names expansion, cupping and peaking as humid season risks. Cooler homes in Phoenix and Tucson average about 70% RH on July and August afternoons, and a dripping register wets wood directly.
Should I run a humidifier in winter if I have a swamp cooler?
If you want to keep the floor inside the warranty band, yes. Bruce recommends a humidifier in the heating season to prevent shrinkage gaps. The cooler is shut down for winter, so it does nothing for winter humidity.
Sources and further reading
- Wood Handbook: Wood as an Engineering Material, FPL-GTR-282 (2021): Chapter 4, Equation 4-5 and Tables 4-2, 4-3 and 4-4; Chapter 10, interior RH and EMC; Chapter 13, Equations 13-3 and 13-4 and Tables 13-2 and 13-5, USDA Forest Service, Forest Products Laboratory
- Hardwood Flooring Limited Warranty Guide (WB-1018-1019-WTRPRF), Bruce, AHF Products
- Hardwood Flooring: Moisture Control and Acclimation Guidelines, Hurst Hardwoods
- POWER hourly API: T2M, T2MDEW and PS, 2021 to 2025, for Phoenix, Tucson, Las Vegas, Albuquerque, El Paso and Denver, NASA Langley Research Center, POWER Project
- PsychroLib: psychrometric functions based on ASHRAE Handbook Fundamentals, PsychroLib project