Maintenance

Can a Swamp Cooler Catch Fire?

Yes, rarely. Cooler fires start at the pump, the blower motor or the wiring and spread to dry pads. The two CPSC pump recalls, and the checks that prevent it.

Short answer

Yes, but rarely. A swamp cooler fire starts at an electrical part: the water pump, the blower motor, or the wiring and cord. The heat then reaches pads that have dried out. Two CPSC recalls show the scale: about 150,000 Dial D5500 pumps with 119 reported fires (1992), and about 150,000 Little Giant CP1, CP2 and CP3 pumps with 26 (2004). To prevent it, replace a weak pump, keep the motor oiled and its belt and pulley set so amps stay under the nameplate, treat a motor that cycles on and off as a warning, replace damaged cords, and turn the power off before any work.

Key takeaways

  • Yes, a swamp cooler can catch fire. It starts at the pump, the blower motor or the wiring, and spreads to pads that have dried out. Wet pads are not the fuel.
  • The CPSC has recalled two cooler pumps for fire: about 150,000 Dial D5500 pumps (119 reported fires, 98 around El Paso) and about 150,000 Little Giant CP1, CP2 and CP3 pumps (26 reported fires).
  • Those counts work out to about 1 reported fire per 1,260 Dial pumps and 1 per 5,800 Little Giant pumps. Rare, but a fire captain in Tucson said he saw cooler fires several times a month each summer.
  • A motor that stops and restarts by itself is its thermal overload working. Champion lists the causes: low voltage, a tight belt, a tight shaft, dry bearings or a pulley set too large.
  • Turn off the power and unplug the motor and pump before you open the cooler. A thermostat is not a disconnect.
On this page
  1. What can burn in a swamp cooler
  2. The fire record: recalls and reports
  3. The three ways a cooler fire starts
  4. Swamp cooler fire safety checklist
  5. Quick rulings
  6. What this answer does not cover
  7. Frequently asked questions

Yes, a swamp cooler can catch fire, but it is rare. The fire starts at an electrical part: the water pump, the blower motor, or the wiring and cord. The heat then reaches pads that have dried out. The U.S. Consumer Product Safety Commission (CPSC) has recalled two cooler pumps for fire. One had 119 reported fires, the other 26, out of about 150,000 pumps each.

Most cooler fires are preventable with checks you can do at spring startup. This page gives the record and the three ways a fire starts. Then comes a checklist. It draws on the Champion and Phoenix manuals and on fire services in Arizona and Australia.

What can burn in a swamp cooler

A swamp cooler (an evaporative cooler) is a metal or plastic box, often on the roof. A small pump lifts water from a pan at the bottom and wets pads in the sides. A blower motor turns a fan that pulls outdoor air through the wet pads and into the house. Water evaporating off the pads cools the air.

So a cooler holds three things together: electricity, moving parts that make heat, and pads. The common pad is aspen, a mat of thin wood shavings. KOLD in Tucson put it bluntly: "a box full of straw, electricity and water can be a rooftop fire hazard."

That raises the question most people actually have. Isn't it all wet? While the pump runs, yes. But pads dry out when the pump fails. And Champion's manual says its coolers "may be used without water for ventilation purposes." In that mode the fan runs and the pads stay dry. Adam Goldberg is a captain with Northwest Fire near Tucson. He told KOLD that an old or badly installed fan motor can overheat. "That heat spreading to dry pads is instant fire."

The safety part that stops most of this is the thermal overload. It is a small heat switch inside the motor and the pump. Champion says each has "an automatic thermal overload switch which will shut motor off when it overheats." Then "the motor will restart automatically when it cools down." The pump also "has automatic reset thermal protection." Keep that switch in mind. It explains the warning sign in the worked example below.

The fire record: recalls and reports

No agency publishes a count of swamp cooler fires. What exists is the recall record and reports from fire services. A search of the CPSC recall database for cooler pumps and evaporative coolers returns two fire recalls, both for pumps.

Swamp cooler fire recalls and reports, from the cited sources
SourceWhat failedUnitsFires reportedDamage
CPSC and Dial, Release 93-003, October 15, 1992Dial D5500 pump, all blue, "1990 Taiwan" on the bottom, sold 1990 and 1991. Misaligned motor bearings could make it fail and "catch fire."150,000119 since 1990; 98 in the El Paso, Texas areaMost damaged cooler cabinets and/or home roofs. No injuries.
CPSC and Little Giant, Recall 05011, October 13, 2004Little Giant CP1, CP2 and CP3 pumps with a light blue motor cap. Sold February 2003 to August 2004 for $35 to $85. The cap was not flame-retardant, and "an internal electrical failure can ignite the cap."About 150,00026Two with property damage
KOLD Tucson, June 30, 2008A rooftop cooler about two years old. Firefighters said an electrical problem with the motor started it.One homeNorthwest Fire saw "similar fires several times a month during the Summer"Firefighters kept it from spreading to the house
CFA Victoria, January 12, 2017Evaporative cooling systems in outer MelbourneFour homes in one weekend4Each fire was contained to the cooling unit

Divide the fires by the pumps sold. That gives about 1 reported fire for every 1,260 Dial pumps. For Little Giant it is 1 for every 5,800. These are fires reported to the maker, so the true count may be higher. Even so, these were pumps with a known defect. That is why "rare" is the honest word. It is also why "it can't happen" is wrong: the Tucson captain was seeing these fires every few weeks in summer.

Two remedies are worth knowing. Little Giant told owners to "stop using the pump immediately" and get a free replacement cap. Beige caps were not part of the recall. Dial told owners of the blue 1990 pump to "stop using their evaporative coolers until the pump is replaced." Dial also noted that economy pumps like the D5500 "reportedly last only one season." Yet some were still in service. Old cheap pumps outlast their welcome.

The three ways a cooler fire starts

1. The pump

The pump sits in the pan and runs every hour the cooler cools. Both recalls were pumps. One failed through bad bearings, the other through an electrical fault that lit its plastic cap. Goldberg's advice was to "replace the water pump and pads at least once a year" and keep the water lines clear. Our pump not working guide covers a pump that hums but will not turn, and the replacement pump guide covers what to buy.

2. The blower motor

The motor is the biggest electrical load in the cooler, and the Tucson fire started there. A motor overheats when it works harder than its nameplate allows. Champion's troubleshooting chart names three causes of an overheated motor. They are a belt too tight, dry blower bearings, and a motor pulley set too large. Dry or misaligned bearings make a shaft drag, which is the same fault behind the Dial pump recall. Goldberg added a plain test: "A healthy motor should not sound squeaky."

A worn belt is not on the fire record by itself. It matters through the motor. Champion says a 3 lb push should deflect the belt 3/4 inch. Tighter than that, the motor overheats. Phoenix adds two rules that also come down to motor load. First, do not remove panels while the cooler runs. That "may cause the blower (fan) motor to overload and damage the motor windings." Second, an improper pulley setting "will overload and severely damage motor windings."

3. Wiring, cords and controls

Champion says the hookup should be done by "a qualified electrician." Phoenix says "qualified person(s)." Phoenix also requires a ground wire between the cooler and the power source. Champion's motor and pump come with a grounded, molded plug. Its chart says to replace a cord if it is damaged. Both makers carry the same warning. "To reduce the risk of fire or electric shock," do not use the fan with any solid-state speed control device. That means no plug-in dimmers or fan speed knobs. The Phoenix PD and PH manual also says to use only the motor and pump combinations marked on the cooler's nameplate.

A breaker that trips is the wiring protecting itself, and a bigger breaker removes that protection. See why a swamp cooler keeps tripping the breaker before you reset it twice.

Worked example: a motor that stops and starts by itself

Take a rooftop cooler with a 3/4 hp motor. Say its nameplate reads 10.2 amps. On a hot afternoon the fan stops, but the breaker is still on. Twenty minutes later it starts again on its own. Nobody touched it.

That is the thermal overload doing its job. The motor got hot enough to trip the switch, cooled, and reset. Champion's chart calls this "motor cycles on and off." It lists five causes. They are low voltage, too much belt tension, a blower shaft tight or locked, dry bearings, and a motor pulley set too large.

Work through it with the power off and the motor unplugged. Spin the blower wheel by hand. If it drags, oil the bearings. Champion says a few drops of non-detergent 20/30 oil once a year. Do not use more, because "over oiling can cause motor burn out." Push the belt. If 3 lb moves it less than 3/4 inch, loosen it. Then put the panels back, wet the pads, and read the running amps with a clamp meter. Say it reads 11.8 amps. That is about 16 percent over the 10.2 on the plate. Champion's fix is to "adjust pulley so full load ampere rating of motor is not exceeded." Opening the adjustable pulley lowers the amps.

The point: a cycling motor is not a quirk to live with. Each cycle means the motor reached the heat its own switch was set to stop. If the switch fails, nothing else stops the heat, and the pads sit right beside the motor.

Swamp cooler fire safety checklist

Power off first: Champion says to "Always turn OFF POWER and UNPLUG motor and pump inside the cooler" before any work. Phoenix warns that "more than one disconnect switch may be required." It adds that a thermostat must not be used as the disconnect, "as it may reset and start the unit unexpectedly."

  1. Check the pump. Look for a light blue Little Giant CP1, CP2 or CP3 cap or an all blue Dial D5500 marked "1990 Taiwan." Replace either. Replace any pump that hums, runs hot or looks melted. Goldberg's rule is a new pump each year.
  2. Spin the blower and listen to the motor. The wheel should turn freely. A squeak, drag or rub means bearings. Oil ported bearings once a year, lightly.
  3. Set the belt. 3 lb should deflect it 3/4 inch (Champion) or 1/2 to 3/4 inch when squeezed (Phoenix). Replace it if worn (Champion). Our belt and pulley guide has the steps.
  4. Read the amps. With pads wet and panels on, running amps should not exceed the nameplate. The motor guide explains the reading.
  5. Check cords and plugs. Look for cracked jackets, scorched plugs and loose or melted connectors inside the cabinet. Replace damaged cords. Do not add a solid-state speed control.
  6. Check that the pads wet fully. Champion says to check "that all pads are saturated with water and that there are no dry spots." South Australia's fire service says a pre-summer service should "check for any faults (water flow and all bearings)" and clean the pads.
  7. Keep panels on. Never run the cooler with a pad or panel removed (Phoenix).
  8. Do not leave it running when you are away. South Australia's fire service says not to leave cooling equipment "running unattended while not at home."
  9. Act on a burning smell. Switch off at the breaker and find the cause; our cooler smells guide sorts burning from musty.

Quick rulings

Swamp cooler fire risk: what to do, from the sources above
What you findRulingSource
Light blue Little Giant CP1, CP2 or CP3 capStop using the pump; recalledCPSC 05011
All blue Dial D5500 marked "1990 Taiwan"Stop using the cooler until the pump is replacedCPSC 93-003
Motor stops and restarts by itselfOverload tripping: check voltage, belt, shaft, bearings, pulleyChampion SM manual
Running amps above the nameplateAdjust the pulley until amps are at or under the plateChampion SM manual; Phoenix PD and PH manual
Squeaky motor or dragging wheelOil or replace bearingsKOLD (Goldberg); Champion SM manual
Damaged cordReplace itChampion SM manual
Plug-in fan speed control or dimmerDo not use oneChampion SM manual; Phoenix FD and FS manual
Pump a year old or moreReplace it at startupKOLD (Goldberg)

What this answer does not cover

The recall counts are reports to the maker, and the Tucson figure is one captain's word, not a statistic. Nobody publishes how many cooler fires happen each year, so this page cannot give your odds. The checks come from Champion SM and Phoenix FD, FS, PD and PH manuals. Other brands set their own belt, oil and amp limits, so read your nameplate and manual. A newer pump is not proof against a defect: both recalls were of new products. Check the CPSC site for your model.

The fixes on this page are owner checks with the power off. Wiring inside the junction box, a new circuit or a breaker change is electrician work, and both makers say so. If you smell burning, see smoke, or find melted plastic, keep the power off and call a technician. If there are flames, call 911 and stay off the roof. Portable coolers have their own cord rules; see the extension cord guide.

Frequently asked questions

Can a swamp cooler catch fire if the pads are wet?

The fires on record start at an electrical part, not the pads. The danger is a pad that has dried out, which happens when the pump fails or the cooler runs as a fan without water. A Tucson fire captain told KOLD that heat from an overheating motor reaching dry pads "is instant fire."

Is my old cooler pump one of the recalled ones?

Check two things. A Little Giant CP1, CP2 or CP3 with a light blue motor cap, sold February 2003 to August 2004, is recalled; beige caps are not. A Dial D5500 that is all blue with "1990 Taiwan" on the bottom is recalled. Both recalls say to stop using the pump.

What does a burning smell from a swamp cooler mean?

Treat it as electrical. Turn the cooler off at the switch and the breaker, then check the motor and pump for heat. Do not restart it until you find the cause.

Is it safe to leave a swamp cooler running when no one is home?

South Australia's Metropolitan Fire Service advises against leaving cooling equipment running unattended while you are away. KOLD's Tucson fire was found by neighbors who called 911 while the owner was out.

Can I use a dimmer or plug-in speed control on a cooler motor?

No. Champion and Phoenix manuals both warn that to reduce the risk of fire or electric shock, the cooler fan must not be used with any solid-state speed control device.

Sources and further reading

  1. CPSC, Little Giant Pump Co. Announce Recall of Cooler Pumps (Recall 05011, October 13, 2004), U.S. Consumer Product Safety Commission
  2. Dial Replaces 1990 D5500 Evaporative Water Cooler Pump (Release 93-003, October 15, 1992), U.S. Consumer Product Safety Commission
  3. Recall records for "cooler pump" (search used for both recalls above), U.S. Consumer Product Safety Commission, SaferProducts.gov Recalls API
  4. Swamp Coolers Can Be A Fire Hazard (Suleika Acosta, June 30, 2008), KOLD News 13, Tucson
  5. Evaporative coolers cause house fires (January 12, 2017), Country Fire Authority, Victoria
  6. Home fire safety fact sheet: Home Cooling (January 2020), South Australian Metropolitan Fire Service
  7. Owners' Manual, 3000 SM, 4000 SM, 4500 SM, 5500 SM, 6500 SM, Champion Cooler Corporation (hosted by Appliance Factory Parts)
  8. Owner's Guide, Use and Care Manual, Ducted Cooler Models FD350, FD450, FD650, FS350, FS450, FS650, Phoenix Manufacturing, Inc.
  9. Owner's Guide, Use and Care Manual, Ducted Cooler Models PD4802, PD6802, PH4802, PH6802 and others, Phoenix Manufacturing, Inc. (hosted by Appliance Factory Parts)